3 Phase RS702 Relay Protection Device 0.5 Class Output Accuracy

3 Phase RS702 Relay Protection Device 0.5 Class Output Accuracy
3 Phase RS702 Relay Protection Device 0.5 Class Output Accuracy

Large Image :  3 Phase RS702 Relay Protection Device 0.5 Class Output Accuracy

Product Details:
Place of Origin: China
Brand Name: RISING
Certification: ISO CE
Model Number: RS702
Payment & Shipping Terms:
Minimum Order Quantity: 1 SET
Packaging Details: Wooden package
Payment Terms: L/C, L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 SET PER Month
Detailed Product Description
Output Accuracy: 0.5 Class Phase: 3 Phase
Phase Output Current: 0-40A Number Of Harmonic: 1-20 Times
Power: Electronic Three Parallel Phase: 0~120A
Phase Current Output (effective Value: 0~40A
High Light:

3p Relay Protection Testing Device

,

0.5 Class relay protection tester

3/6 Phase Relay Protection Tester RS702 0.5 Class Output Accuracy

 

Product Description

Advantage

1. 6 Phase Relay Protection Tester  satisfies all requirements of field test.
The tester can simultaneously output standard six-phase current and six-phase voltage with 30A/phase current and 125V/phase voltage. Connecting six phase current in parallel can acquire 180A current. The tester can not only test traditional relays and protective devices, but also test modern microcomputer-based protective devices, especially the differential protection of transformers and automatic switching devices of stand-by power supply. Testing becomes more convenient and perfect.
2. All technical parameters meet the criteria DL/T624-1997 Technical Specifications of Test Equipment Based on Micro-computer for Relaying Protection.
3. The host machine, which has embedded high performance IPC (industrial personal computer), can run independently with its 300—600MHz main frequency, 128M memory, 6—12G hard disk and Windows XP operating system.
4. It was the first one in the industry to apply imported stainless steel panel, stainless steel keypad, touch-pad mouse, which overcomes such defects of trackball mouse as difficulty in operating and prone to damage. The TFT true color display is employed with a size of 8.4 inch and its resolution being 800×600. Consequently, the overall operation of the host machine becomes convenient and durable.
5. The main control board is of DSP+FPGA structure, outputting 16 bit DAC, which may generate 2000 points high density sine wave per week to fundamental wave, greatly ameliorate the quality of waveform and improve the accuracy of tester.
6. The power amplifier is hi-fi linear type, which can both guarantee the precision of low current and the stability of heavy current.
7. The device can directly access to PC machine through USB interface, needless of any patch cord.
8. The device can run by access to notebook computer, which is installed with a same software, needless to relearn how to operate.
9. The device has GPS synchronous testing function with embedded synchronization card (matching), which accesses to PC machine through RS232 interface, so the synchronous testing by exchanging two testers in different places can be achieved.

Feature/Function
1. AC current output
1) Output accuracy: 0.5 level
2) Phase current output (effective value): 0 ~ 40A
3) Three parallel current output (effective value): 0 ~ 120A
4) Allowable working value (effective value) of phase current for a long time: 10A
5) Maximum output power of phase current: 420VA
6) Maximum output power at maximum output of triple current: 900VA
7) Allowable working time at maximum output of triple current: 10s
8) Frequency range (fundamental wave): 20 ~ 1000Hz
9) Harmonic frequency: 1 ~ 20 times
2. DC current output
1) Output accuracy: 0.5 level
2) Current output: 0 ~ ± 10A / each phase, 0 ~ ± 30A / triple
3) Maximum output load voltage: 20V
3. AC voltage output
1) Output accuracy: 0.5 level
2) Phase voltage output (effective value): 0 ~ 120V
3) Line voltage output (effective value): 0 ~ 240V
4) Phase voltage / line voltage output power: 80VA / 100VA
5) Frequency range (fundamental wave): 20 ~ 1000Hz
6) Harmonic frequency: 1 ~ 20 times
4. DC voltage output
1) Output accuracy: 0.5 level
2) Phase voltage output amplitude: 0 ~ ± 160V
3) Line voltage output amplitude: 0 ~ ± 320V
4) Phase voltage / line voltage output power: 70VA / 140VA
5. Switch quantity and time measurement