Home ProductsTransformer Test Bench

CE OEM 300A Transformer Test Bench

China Wuhan Rising Electric Co., Ltd. certification
China Wuhan Rising Electric Co., Ltd. certification
I bought a transformer test bench this January.It is really very good quality,runs very stable.

—— Mahmoud

I am lucky that I did select RISING's Relay Tester.

—— Mr.Abdul

Considering for a long time then ordered a TTR from RISING.It is cool.Good quality,advanced,smart and nice appearance

—— Mr.Shazab

I'm Online Chat Now

CE OEM 300A Transformer Test Bench

CE OEM 300A Transformer Test Bench
CE OEM 300A Transformer Test Bench

Large Image :  CE OEM 300A Transformer Test Bench

Product Details:
Place of Origin: China
Brand Name: RISING
Certification: ISO CE
Model Number: RSBTT III
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Packaging Details: Wooden package for export
Delivery Time: 20 working days
Payment Terms: T/T, Western Union, MoneyGram,L/C, D/A, D/P,
Supply Ability: 100 SET PER Month
Detailed Product Description
Voltage: 0.1-800V Current: 0.1-300A
Power: U*I Power Factor: 0.1-0.9999
Power Supply: AC380V±10% 50Hz±2% Working Temperature: 0-40℃
Relative Humidity: 30%-90% Outline Dimension: Customization
High Light:

transformer test bed

,

transformer testing bed

Full Automatic Transformer Test Bench OEM Customized Transformer Test Bed Automatic Transformer Test Bench

Product Description

Transformer test bench, integrated transformer test bed, transformer characteristic test bed

This product meets the national standard: GB/T4776,GB/T5169,GB/4285.

This product mainly used for transformer, load & no-load substation transformer characteristics, also can do double frequency induction and voltage withstand tests. The measuring parts of the device are imported from foreign countries, digital display, the on-load, short circuit data are sampled by single clip, avoid the error caused by voltmeter, ammeter , watt meter separately reading and calculated by people using traditional methods.

 

 

Electrical test bench manufacturers Performance indicators:

1. Tested transformer parameters

1.1 Transformer capacity under test (to meet temperature rise test condition, dry type transformer)

10kV level ≤2500KVA

35kV level ≤6300kVA

1.2 Tested transformer voltage level below 35kV on primary side

2. Accuracy

2.1 Voltage Range 0-22kV

2.2 Current Range 0-400A

2.3 Minimum voltage resolution 0.001V* PT ratio

2.4 Minimum current resolution 0.0001A*CT ratio

2.5 Power Minimum Resolution 0.1W*PT Ratio*CT Ratio

2.6 Ambient temperature -10~45°C

2.7 Using Relative Humidity 85%

 
Technical Parameters:
Item
Scope of Measurement
Relative Error
Voltage
0.1-800V
±(0.2% reading + 0.1% range)
Current
0.1-300A
±(0.2% reading + 0.1% range)
Power
U*I
±(0.2% reading + 0.1% range)
Power factor
0.1-0.9999
±3 figures
Power supply
AC 380V±10% 50Hz±2%
Operating condition
Working temperature: -20℃-40℃ Relative humidity <90%