Home ProductsCT PT Testing Equipment

RSHJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer

China Wuhan Rising Electric Co., Ltd. certification
China Wuhan Rising Electric Co., Ltd. certification
I bought a transformer test bench this January.It is really very good quality,runs very stable.

—— Mahmoud

I am lucky that I did select RISING's Relay Tester.

—— Mr.Abdul

Considering for a long time then ordered a TTR from RISING.It is cool.Good quality,advanced,smart and nice appearance

—— Mr.Shazab

I'm Online Chat Now

RSHJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer

RSHJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer
RSHJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer RSHJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer

Large Image :  RSHJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer

Product Details:
Place of Origin: China
Brand Name: RISING
Certification: ISO CE
Model Number: HJ-80KV
Payment & Shipping Terms:
Minimum Order Quantity: 1 SET
Packaging Details: Wooden package
Payment Terms: L/C, L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 SET PER Month
Detailed Product Description
Power Factor: 1.0 Capacity: 80VA
Frequency: 50/200Hz Usage: Instrument
The Primary Voltage: 10√3-80√3KV The Secondary Voltage: 0.1√3KV
Induced Withstand Voltage: 92kV Name: Standard Voltage Transformer
High Light:

secondary load tester

,

secondary load instrument

 

HJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer

 

Product Description

  • Purpose

The function of the transformer is to reduce the ac voltage and the large current in proportion to the value that can be directly measured by the instrument, so as to facilitate the direct measurement by the instrument, and at the same time to provide power for relay protection and automatic devicesThe transformer can measure the voltage, current and electric energy of the primary system in coordination with the measuring instrument and measuring device.Together with relay protection and automatic devices, it can constitute electrical protection and automatic control for various faults of the power grid.

  • Conditions of use

Ambient temperature:0°C -- +40°C; Relative humidity should be greater than 80%

  • Use and maintenance

Due to the dry structure of the product,the storage place must be dry to prevent violent collision.

  Technical Parameters  

Temperature: -5 ─ +40℃

Humidity < 80%

Capacity:80 VA

Power Factor:1.0

The Primary Voltage 10√3-803KV

The Secondary Voltage 0.13KV

Accurate Level: 0.01 lever

Frequency:50/200Hz

Induced Withstand Voltage 92kV

Rated Capacity:1VA

Contact Details
Wuhan Rising Electric Co., Ltd.

Contact Person: Jason

Tel: +8613036102793

Send your inquiry directly to us (0 / 3000)