Product Details:
Payment & Shipping Terms:
|
Power: | Electronic, <200W | Amplitude Measurement Range: | (-100dB)~(+20dB) |
---|---|---|---|
Amplitude Measurement Accuracy: | ±1dB | Weight: | 2.0, 2.5, 3.0, 3.5kV/s (adjustable) |
Instrument Dimension: | 300*340*120mm3 | Case Dimension: | 310*400*330mm3 |
High Light: | High Precision SFRA Test Equipment,ISO SFRA Test Equipment,RSBX-H Microprocessor Control Transformer Testing Equipment |
RSBX-H High Precision SFRA Test Equipment / Transformer Winding Deformation Tester
Product Introduction
Product Features
1.Use high-speed, high integration microprocessor to sample and control.
2.Use USB to connect the notebook PC and device.
3.Communication wireless Bluetooth interface between the laptop and instruments.
4.Hardware cassette mechanism adopts DDS (from America), can correctly detect the breakdown :distortion, swell, shift, tilt, inter-turn short circuit deformation and contacting short circuit inter-phase.
5.High-speed, dual channel, 16 bit A/D sampling (the wave from curve will change obviously if change the tapping switch during the field tests.).
6.The software can adjust the output signal range, the maximum amplitude peak±10V.
7.The computer automatically generating the test results to be Word document.
8.Use precision, high stability components, the same phase repeat test, measurement repetition rate >99.5%.
9.Finished circuit boards, surface specially treatment with anti-water pollution and harmful gases.
10.The device with two measurement system: linear scan and sectional scan.
11.Amplitude-frequency characteristic comply the national technical specifications.
12.Test data automatic analysis system, horizontal compare the similarity of A,B ,C, the results as below:
a.conformance is very good
b.conformance is good
c.conformance is bad
d.conformance is very bad
Vertical compare A-A,B-B,C-C, obtain the original data to compare the winding deformation with the test data in the same phase, the results as below:
a.normal
b.slight deformation
c.moderate deformation
d.serious deformation
13.Automatically generating Word document,convenient for customers to save and print.
Linear scan measurement range | (1kHz)-(2MHz), 2000 scan frequency point, resolution:1kHz |
Sectional scan measurement range | (0.5kHz)~(1MHz), 2000 scan frequency point |
(0.5kHz)~(10kHz) | |
(10kHz)~(100kHz) | |
(100kHz)~(500kHz) | |
(500kHz)~(1000kHz) | |
Amplitude measurement range | (-100dB)~(+20dB) |
Amplitude measurement accuracy | 0.1dB |
Scan frequency accuracy | <0.01% |
Signal input impedance | 1MΩ |
Signal output impedance | 50Ω |
Co-phase repetitive rate | 99.5% |
Instrument dimension | 300×340×120mm3 |
Case dimension | 310×400×330mm3 |
Weight | 10kg |
Contact Person: Jason
Tel: +8613036102793